Refrigeration system failure simulator (25 failures) P.N.: GTRT-0019 Picture for reference:
Description Very complete refrigeration system failure simulator intended for professional training, produced from a multi-evaporator refrigeration system operating at different temperatures allowing technicians to be put into a real maintenance situation. The system is open and can generate 25 different anomalies on the refrigeration circuit and the electrical circuit from push-button switches. Tool kits and professional refrigeration maintenance equipment are available as options. Supplied with complete educational operating manual with practical work (TP).
Educational operations The bench allows the following practical work (TP) to be carried out: Simulation of 25 different failures on the refrigeration circuit and the electrical circuit: - Compressor valve fault - Oil separator fault - Overload - Under charge - Check valve leak - Evaporator pressure regulator fault - Thermostatic expansion valve not working - freezer evaporator - Thermostatic expansion valve anomaly - freezer evaporator - Thermostatic expansion valve not working - refrigeration cold room evaporator - Thermostatic expansion valve anomaly - cold freezer evaporator - Positive cold room evaporator suction pipe - frosted - Positive cold room evaporator suction line - frosted - Filter drier restriction - Discharge pressure anomaly - Malfunction of the hot gas defrosting system - Suction pressure too low - reducing the capacity of the evaporator - Suction pressure too high - Phase anomaly - Anomaly on two phases - A disconnected contact set (motor overload protection) - Two sets of disconnected contacts (motor overload protection) - Motor switch box thermal overload protection - Coil anomaly - motor protection - starter box - Thermostatic anomaly - freezing chamber - not working - Thermostatic anomaly - refrigeration chamber - not working Supplied with complete educational operating manual with practical work (TP). Tender Specifications REFRIGERATION SYSTEM FAILURE SIMULATOR The bench must allow the following educational operations: Simulation of 25 different failures on the refrigeration circuit and the electrical circuit: - Compressor valve fault - Oil separator fault - Overload - Under charge - Check valve leak - Evaporator pressure regulator fault - Thermostatic expansion valve not working - freezer evaporator - Thermostatic expansion valve anomaly - freezer evaporator - Thermostatic expansion valve not working - refrigeration cold room evaporator - Thermostatic expansion valve anomaly - cold freezer evaporator - Positive cold room evaporator suction pipe - frosted - Positive cold room evaporator suction line - frosted - Filter drier restriction - Discharge pressure anomaly - Malfunction of the hot gas defrosting system - Suction pressure too low - reducing the capacity of the evaporator - Suction pressure too high - Phase anomaly - Anomaly on two phases - A disconnected contact set (motor overload protection) - Two sets of disconnected contacts (motor overload protection) - Motor switch box thermal overload protection - Coil anomaly - motor protection - starter box - Thermostatic anomaly - freezing chamber - not working - Thermostatic anomaly - refrigeration chamber - not working
Technical specifications required: - Device mounted on a frame with wheels with a stainless steel base and rear panel. - Semi-hermetic compressor, 1.5 kW. 1450rpm - Air-cooled condenser, aluminum fins, copper coil. - Evaporators: Showcase evaporators. Aluminum fins, Copper coils with hot gas defrost - Injection controls: Two thermostatic expansion valves and a liquid reservoir - Control equipment: High and low pressure adjustment, thermostatic control, evaporator pressure control, cooling capacity adjustment, condensation pressure and crankcase pressure adjustment, low and high pressure pressure switches. - Instruments - Digital temperature indicator with 10 measurement channels - 4 pressure gauges (3 vacuum gauges, 1 high pressure) - 2 dial thermometers - Hand-held digital multimeter - Refrigerant: R134a. - Panel mounted electrical control box including easily accessible three phase relays, fuses and overload protector. A built-in three-phase residual current device protects against earth leakage. The fan speed control and the defrost switch with its indicator will also be mounted on the panel. - Supplied with user manual with practical work Size: 1800*850*1800mm Weight: about 180kg Power supply: AC380V/50Hz